| 1. Types
Blowing type: insulated type with wave radiator, uninsulated type with wave radiator, insulated type with inserted foil radiator, insulated type with comb radiator.
Heater with fan: insulated type with fan, uninsulated type with fan.
Convecting type air heater. |
2. Some appliances.
Blowing type: room heater, bathroom heater, air conditioner heater, drying room heater, clothes dryer, hand dryer, air conditioner system for electric car, discharging loader for battery.
Convecting type: moistureproof and dew proof for electronic equipments, heating for electronic controll case, room heater. |
| |
3. Notice in appliance.
Blowing type:
1) This type of PTC air heater need a fan to blow, usually the faster is the air blowing speed, the larger is the power;
2)
When PTC is used in very low ambient temperature, it have to be special designed;
3) PTC heater do not be damaged without air blowing, but the power is very low;
4) The power could be adjusted by air blowing speed; or it could be adjusted by voltage; or changing the number of heaters.
5)
The surface tempetature on heater would be higher without air blowing. A thermostat could be assembled on the heater, preventing the damage of the holde;
6)
The surface temperature on dispersion plate is closed to the curie temperature, without air blowing; but the surface temperature on dispersion plate will be lower than the curie temperature very much, with air blowing;
Convecting type.
1) Heating power depends on assembling methods, direction of the heater;
2)
Keep air flowing itself for heat could be diffused;
3)
The heating power will be increased 2~4 times, when the heater is blowed;
4)
The heating power will be increased, when the heater is assembled on a metal holder.
|
| |
4. Current products.
Blowing type.
Uninsulated air heater. |

|
Part number |
Length
/mm |
Width
/mm |
Thickness
/mm |
Rate voltage
/V |
Switch temperature
/℃ |
Power /W
(5m/s, airflow) |
MZFR-8.5J96Z44-220V1 |
96 |
44 |
15 |
220 |
250 |
850 |
MZFR-10.6J120Z44-220V1 |
120 |
44 |
15 |
220 |
250 |
1060 |
MZFR-12.8J96Z66-220V1 |
96 |
66 |
15 |
220 |
250 |
1280 |
MZFR-16J120Z66-220V1 |
120 |
66 |
15 |
220 |
250 |
1600 |
Notice:
1) Customer’s required power and dimensions was possible; the larger is the area of radiator, the larger is the heating power;
2) 6~400V of rated voltage, DC or AC, are possible;
3) UL file for PTC pellet: E207611;
4) 80~250℃ of switch temperature is posible; the power is direct ratio with temperature difference (ΔT = switch temperature-ambient temperature). |
|
| Uninsulated air heater with low windage resistance. |

|
Part number |
Length
/mm |
Width
/mm |
Thickness
/mm |
Rate voltage
/V |
Switch temperature
/℃ |
Power /W
(5m/s, airflow) |
MZFR-0.9J48Z23-220V2 |
48 |
23 |
20 |
220 |
150 |
90 |
MZFR-1.8J48Z46-220V2 |
48 |
46 |
20 |
220 |
150 |
180 |
MZFR-1.3J72Z23-220V2 |
72 |
23 |
20 |
220 |
150 |
130 |
MZFR-2.5J72Z46-220V2 |
72 |
46 |
20 |
220 |
150 |
250 |
MZFR-1.6J48Z23-220V2 |
48 |
23 |
20 |
220 |
250 |
160 |
MZFR-3.2J48Z46-220V2 |
48 |
46 |
20 |
220 |
250 |
320 |
MZFR-2.4J72Z23-220V2 |
72 |
23 |
20 |
220 |
250 |
240 |
MZFR-4.6J72Z46-220V2 |
72 |
46 |
20 |
220 |
250 |
460 |
Notice:
1) Customer’s required power and dimensions was possible; the larger is the area of radiator, the larger is the heating power;
2) 6~400V of rated voltage, DC or AC, are possible;
3) UL file for PTC pellet: E207611;
4) 80~250℃ of switch temperature is posible; the power is direct ratio with temperature difference (ΔT = switch temperature-ambient temperature). |
|
Insulated air heater. |
 |
Part number |
Length
/mm |
Width
/mm |
Thickness
/mm |
Rate voltage
/V |
High pot
voltage
/V |
Switch temperature
/℃ |
Power /W
(5m/s, airflow) |
MZFRJ-6.4J96Z50-220V1 |
96 |
50 |
20 |
220 |
3750 |
250 |
640 |
MZFRJ-8.0J120Z50-220V1 |
120 |
50 |
20 |
220 |
3750 |
250 |
800 |
MZFRJ-9.6J96Z75-220V1 |
96 |
75 |
20 |
220 |
3750 |
250 |
960 |
MZFRJ-12J120Z75-220V1 |
120 |
75 |
20 |
220 |
3750 |
250 |
1200 |
MZFRJ-6.4J96Z50-110V1 |
96 |
50 |
20 |
110 |
2500 |
250 |
640 |
MZFRJ-8.0J120Z50-110V1 |
120 |
50 |
20 |
110 |
2500 |
250 |
800 |
MZFRJ-7.2J72Z75-110V1 |
72 |
75 |
20 |
110 |
2500 |
250 |
720 |
MZFRJ-9.6J96Z75-110V1 |
96 |
75 |
20 |
110 |
2500 |
250 |
960 |
Notice:
1) Customer’s required power and dimensions was possible; the larger is the area of radiator, the larger is the heating power;
2) 6~400V of rated voltage, DC or AC, are possible;
3) UL file for PTC pellet: E207611;
4) 80~250℃ of switch temperature is posible; the power is direct ratio with temperature difference (ΔT = switch temperature-ambient temperature). |
|
Insulated air heater with low windage resistance. |
 |
Part number |
Length
/mm |
Width
/mm |
Thickness
/mm |
Rate voltage
/V |
High pot
voltage
/V |
Switch temperature
/℃ |
Power /W
(5m/s, airflow) |
MZFRJ-2.2J77Z28-220V2 |
77 |
28 |
15 |
220 |
3750 |
250 |
220 |
MZFRJ-4.0J77Z56-220V2 |
77 |
56 |
15 |
220 |
3750 |
250 |
400 |
MZFRJ-6.0J77Z84-220V2 |
77 |
84 |
15 |
220 |
3750 |
250 |
600 |
MZFRJ-2.3J77Z28-220V3 |
77 |
28 |
20 |
220 |
3750 |
250 |
230 |
MZFRJ-4.5J77Z56-220V3 |
77 |
56 |
20 |
220 |
3750 |
250 |
450 |
MZFRJ-6.5J77Z84-220V3 |
77 |
84 |
20 |
220 |
3750 |
250 |
650 |
Notice:
1) Customer’s required power and dimensions was possible; the larger is the area of radiator, the larger is the heating power;
2) 6~400V of rated voltage, DC or AC, are possible;
3) UL file for PTC pellet: E207611;
4) 80~250℃ of switch temperature is posible; the power is direct ratio with temperature difference (ΔT = switch temperature-ambient temperature). |
| |
| Insulated multi-slice herater. |

|
 |
Part number |
Length of heating part/mm |
Height
/mm |
Width
/mm |
Applied voltage /V |
High pot
voltage
/V |
Switch temperature
/℃ |
Power /W
(5m/s, airflow) |
MZFRJ-9.0J100Z60-220V4 |
100 |
60 |
30 |
220 |
3750 |
250 |
900 |
MZFRJ-18J200Z60-220V4 |
200 |
60 |
30 |
220 |
3750 |
250 |
1800 |
MZFRJ-25J100Z60-220V4 |
300 |
60 |
30 |
220 |
3750 |
250 |
2500 |
Notice:
1) Customer’s required power and dimensions was possible; the larger is the area of radiator, the larger is the heating power;
2) 100~400V of rated voltage, DC or AC, are possible;
3) UL file for PTC pellet: E207611;
4) 80~250℃ of switch temperature is posible; the power is direct ratio with temperature difference (ΔT = switch temperature-ambient temperature). |
| Convecting type air heater |
 |
Part number |
Length
/mm |
Width
/mm |
height
/mm |
Rate voltage
/V |
High pot
voltage
/V |
Surface temperature
/℃ |
Power without wind /W |
DL -45W50A-220V1 |
100 |
77 |
40 |
220 |
3750 |
180 |
45 |
DL -90W100A-220V1 |
100 |
77 |
40 |
220 |
3750 |
180 |
90 |
DL -130W150A-220V1 |
150 |
77 |
40 |
220 |
3750 |
180 |
130 |
DL -160W200A-220V1 |
200 |
77 |
40 |
220 |
3750 |
180 |
160 |
DL -30W50A-220V1 |
100 |
77 |
40 |
220 |
3750 |
130 |
30 |
DL -60W100A-220V1 |
100 |
77 |
40 |
220 |
3750 |
130 |
60 |
DL -90W150A-220V1 |
150 |
77 |
40 |
220 |
3750 |
130 |
90 |
DL -110W200A-220V1 |
200 |
77 |
40 |
220 |
3750 |
130 |
110 |
DL -15W50A-220V1 |
100 |
77 |
40 |
220 |
3750 |
80 |
15 |
DL -30W100A-220V1 |
100 |
77 |
40 |
220 |
3750 |
80 |
30 |
DL -40W150A-220V1 |
150 |
77 |
40 |
220 |
3750 |
80 |
40 |
DL -60W200A-220V1 |
200 |
77 |
40 |
220 |
3750 |
80 |
60 |
Notice:
1) Customer’s required power and dimensions was possible; the larger is the area of radiator, the larger is the heating power;
2) 6~400V of rated voltage, DC or AC, are possible;
3) UL file for PTC pellet: E207611;
4) The power would be larger 2~4 time with wind blowing the radiator. |
| |
Air heater including a fan |
 |
Models |
Length
/mm |
Width
/mm |
Thickness
/mm |
Rate voltage
/V |
High pot
Voltage /V |
Power /W |
RF -2500W130A-220V1 |
130 |
130 |
80 |
220 |
uninsulated |
2500 |
RFJ -1500W130A-220V1 |
130 |
130 |
80 |
220 |
3750V |
1500 |
RF -1000W90A-220V1 |
90 |
90 |
80 |
220 |
uninsulated |
1000 |
RFJ -600W90A-220V1 |
90 |
90 |
80 |
220 |
3750V |
600 |
Notice:
1) Customer’s required power was possible;
2) 6~400V of rated voltage, DC or AC, are possible;
3) UL file for PTC pellet: E207611;
4) A thermostat or temperature fuse could be assembled as customer’s required. |
| |
|
|
|